3) Insert the wire into a socket.
When using a single wire or stranded wire without a blade terminal, push an open/close button all the way down with
a flathead screw driver, and insert the wire.
NOTE
When using a stranded wire without a blade terminal, twist enough to avoid short circuit with a nearby terminals or
wires.
Place the flathead screwdriver vertical to the open/close button. In case the blade tip slips, it may cause to damage of
inverter or injury.
Wire removal
Pull the wire with pushing the open/close button all the way down firmly with a flathead screwdriver.
NOTE
Pulling out the terminal block forcefully without pushing the open/close button all the way down may damage the
terminal block.
Use a small flathead screwdriver (Tip thickness: 0.4mm/tip width: 2.5mm).
If a flathead screwdriver with a narrow tip is used, terminal block may be damaged.
Introduced products :(as of Jan. 2010)
Product
Flathead screwdriver
Place the flathead screwdriver vertical to the open/close button. In case the blade tip slips, it may cause to damage of
inverter or injury.
Open/close button
Flathead screwdriver
Open/close button
Flathead screwdriver
Type
SZF 0- 0,4 x 2,5
Phoenix Contact Co.,Ltd.
Control circuit specifications
Maker
2
29

Advertisement