Reference Of The Terminal Fm (Pulse Train Output) (Pr. 55, Pr. 56) - Mitsubishi Electric FR-E720-0.1K(SC) Instruction Manual

Fr-e700 series
Table of Contents

Advertisement

4.12.3 Reference of the terminal FM (pulse train output) (Pr. 55, Pr. 56)

The pulse train output terminal FM is available for monitor output.
Set the reference of the signal output from terminal FM.
Parameter
Name
Number
Frequency monitoring
55
reference
Current monitoring
56
reference
The above parameters can be set when Pr. 160 User group read selection =
The above parameters allow their settings to be changed during operation in any operation mode even if "0" (initial value) is set in Pr. 77 Parameter
write selection.
(1)
Frequency monitoring reference (Pr. 55)
Set the full scale value when outputting the frequency monitor from terminal FM.
Set the frequency to be indicated as the full scale value on the frequency meter (1mA analog meter) connected between
terminal FM and SD. (For example, 60Hz or 120Hz.)
Set the inverter output frequency (set frequency) at which the pulse speed of the FM output is 1440 pulses/s.
The pulse speed and inverter output frequency are proportional to each other. (The maximum pulse train output is 2400
pulses/s.)
2400
1440
1Hz
60Hz
(initial value)
Setting range of Pr. 55
(2)
Current monitoring reference (Pr. 56)
Set the full scale value when outputting the current monitor from terminal FM.
Set the output current at which the pulse speed of the FM output is 1440 pulses/s.
The pulse speed and output current monitor value are proportional to each other. (The maximum pulse train output is
2400 pulses/s.)
2400
1440
Rated current
(initial value)
Setting range of Pr. 56
Monitor display and monitor output signal
Initial Value
60Hz
Inverter
rated current
Output frequency 400Hz
500A
Setting Range
Full-scale value when frequency monitor value is
0 to 400Hz
output to terminal FM.
Full-scale value when current monitor value is
0 to 500A
output to terminal FM.
0
. (Refer to page 188).
"
"
Description
159
4

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents