Function assignment of external terminal and control
Setting
Signal
Second function selection
3
RT
Pr. 270 = 1 ∗2
4
AU
Terminal 4 input selection
5
JOG
Jog operation selection
External thermal relay input ∗3
7
OH
15-speed selection (combination with three speeds RL, RM,
8
REX
RH)
10
X10
Inverter run enable signal (FR-HC, FR-CV connection)
12
X12
PU operation external interlock
14
X14
PID control valid terminal
15
BRI
Brake opening completion signal
PU-External operation switchover (turning ON X16 selects
16
X16
External operation)
18
X18
V/F switchover (V/F control is performed when X18 is ON)
24
MRS
Output stop
25
STOP
Start self-holding selection
Forward rotation command (assigned to STF terminal (Pr. 178)
60
STF
only)
Reverse rotation command (assigned to STR terminal (Pr. 179)
61
STR
only)
62
RES
Inverter reset
PU/NET operation switchover (turning ON X65 selects PU
65
X65
operation)
External/NET operation switchover (turning ON X66 selects
66
X66
NET operation)
Command source switchover (turning ON X67 makes Pr. 338
67
X67
and Pr. 339 commands valid)
9999
No function
∗1
When Pr. 59 Remote function selection = "1" or "2", the functions of the RL, RM and RH signals are changed as given in the table.
∗2
When Pr. 270 Stop-on contact control selection = "1", functions of RL and RT signals are changed as in the table.
∗3
The OH signal turns ON when the relay contact "opens".
NOTE
Changing the terminal assignment using Pr.178 to Pr.184 (input terminal function selection) may affect the other functions.
Set parameters after confirming the function of each terminal.
Same function can be assigned to two or more terminals. In this case, the logic of terminal input is OR.
The priorities of the speed commands are in order of JOG > multi-speed setting (RH, RM, RL, REX) > PID (X14).
When the X10 signal (FR-HC, FR-CV connection-inverter operation enable signal) is not set or when the PU operation
external interlock (X12) signal is not assigned with Pr.79 Operation mode selection set to "7", the MRS signal shares this
function.
Same signal is used to assign multi-speed (7 speeds) and remote setting. They cannot be set individually.
(Same signal is used since multi-speed (7 speeds) setting and remote setting are not used to set speed at the same
time.)
Switch the control method using external terminal (X18 signal) during an inverter stop. If control method between V/F
control and Advanced (General-purpose magnetic) flux vector control is switched during the operation, the actual
switchover does not take place until the inverter stops. In addition, if control method is switched to V/F control during
the operation, only second function becomes valid as V/F control and second function are selected simultaneously in
V/F control.
Turning the AU signal ON makes terminal 2 (voltage input) invalid.
(2)
Response time of each signal
The response time of the X10 signal and MRS signal is within 2ms.
The response time of other signals is within 20ms.
140
Function
Stop-on contact selection 1
Related Parameters
Pr. 44 to Pr. 51
Pr. 270, Pr. 275, Pr. 276
Pr. 267
Pr. 15, Pr. 16
Pr. 9
Pr. 4 to Pr. 6, Pr. 24 to Pr. 27,
Pr. 232 to Pr. 239
Pr. 30, Pr. 70
Pr. 79
Pr. 127 to Pr. 134
Pr. 278 to Pr. 283
Pr. 79, Pr. 340
Pr. 80, Pr. 81, Pr. 800
Pr. 17
Pr. 79, Pr. 340
Pr. 79, Pr. 340
Pr. 338, Pr. 339
Refer to
Page
142
133
176
104
116
102
130
194
246
135
201
84, 86, 89,
120
141
143
143
143
202
202
205

Advertisement

Table of Contents

   Related Manuals for Mitsubishi Electric FR-E720-0.1K(SC)

Comments to this Manuals

Symbols: 0
Latest comments: