(2)
Safety stop function model
Sink logic
Main circuit terminal
Control circuit terminal
Single-phase power input
MCCB
Single-phase
AC power
supply
MCCB
Three-phase
AC power
supply
Control input signals (No voltage input allowed)
Forward
Terminal functions vary
rotation start
with the input terminal
Reverse
assignment (Pr. 178 to
rotation start
Pr. 182 and Pr. 184)
Multi-speed selection
*2 When using terminals PC-
SD as a 24VDC power
supply, take care not to
short across terminals
PC-SD.
Contact input common
24VDC power supply
(Common for external power supply transistor)
Safety stop input common terminal
Safety stop input (Channel 1)
Safety stop input (Channel 2)
Frequency setting signals (Analog)
*3 Terminal input specifications
Frequency
can be changed by analog
setting
input specifications
potentiometer
switchover (Pr. 73).
1/2W1kΩ
*4 It is recommended to use 2W1kΩ
when the frequency setting signal
is changed frequently.
Terminal 4 input
(Current input)
*5 Terminal input specifications can be changed by analog
input specifications switchover (Pr. 267). Set the
voltage/current input switch in the "V" position to select
voltage input (0 to 5V/0 to10V) and "I" (initial value) to
select current input (4 to 20mA).
To use terminal 4 (initial setting is current input), set "4"
in any of Pr.178 to Pr.184 (input terminal function selection)
to assign the function, and turn ON AU signal.
Connector for
plug-in option connection
NOTE
To prevent a malfunction caused by noise, separate the signal cables more than 10cm from the power cables. Also
separate the main circuit wire of the input side and the output side.
After wiring, wire offcuts must not be left in the inverter.
Wire offcuts can cause an alarm, failure or malfunction. Always keep the inverter clean. When drilling mounting holes
in an enclosure etc., take care not to allow chips and other foreign matter to enter the inverter.
The output of the single-phase power input model is three-phase 200V.
*
1. DC reactor (FR-HEL)
When connecting a DC reactor, remove the
jumper across P1 and P/+.
MC
R/L1
Earth
S/L2
(Ground)
Jumper
MC
R/L1
S/L2
T/L3
Earth
(Ground)
STF
STR
RH
High
speed
RM
Middle
speed
RL
Low
speed
RES
Reset
SD
PC *2
S1
Output shutoff
S2
circuit
Shorting wire
3
10(+5V)
2 0 to 5VDC
2
(0 to 10VDC)
*4
5(Analog common)
1
(+)
4 4 to 20mADC
(-)
0 to 5VDC
0 to 10VDC
V
Voltage/current
input switch
Brake unit
(Option)
*1
R
*7
PR N/-
*6
P1
P/+
Inrush current
V
limit circuit
W

Main circuit

Control circuit

C
B
A
RUN
Running
FU
Frequency detection
24V
SE
Calibration resistor
FM
SD
*3
PU
connector
*5
USB
connector
I
*5
Option connector
Wiring
*6 A brake transistor is not built-in to the 0.1K
and 0.2K.
*7 Brake resistor (FR-ABR, MRS, MYS type)
Install a thermal relay to prevent an
overheat and burnout of the brake resistor.
(The brake resistor can not be connected
to the 0.1K and 0.2K.)
Motor
IM
Earth (Ground)
Safety stop function model
Relay output
Terminal functions vary
by Pr. 192 A,B,C terminal
Relay output
function selection
(Fault output)
Open collector output
Terminal functions vary with
the output terminal assignment
(Pr. 190 and Pr. 191)
Open collector output common
Sink/source common
Indicator
+
(Frequency meter, etc.)
-
Moving-coil type
1mA full-scale
*8
*8 It is not necessary when
calibrating the indicator
from the operation panel.
2
15