Mitsubishi Electric FR-E720-0.1K(SC) Instruction Manual page 196

Fr-e700 series
Table of Contents

Advertisement

Selection of operation mode and operation location
(2)
Operation mode switching method
When "0 or 1" is set in Pr. 340
Switching from the network
Switch to the External
operation mode from
the network.
Network operation
When "10" is set in Pr. 340
Network operation
REMARKS
Refer to the following for switching by the external terminal.
PU operation external interlock signal (X12)
PU-external operation switch-over signal (X16)
External-NET operation switchover signal (X65), NET-PU operation switchover signal (X66)
Pr. 340 Communication startup mode selection
196
External operation
Switch to Network operation
mode from the network.
Press
of the PU to light
Press
of the PU to light
Refer to page 200
Refer to page 201
Refer to page 204
Switching from the PU
Press
the PU to light
Press
of
the PU to light
Refer to page 202
of
PU operation
PU operation

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents