Function assignment of external terminal and control
Setting
Signal
Positive
Negative
logic
logic
64
164
Y64
68
168
EV
80
180
SAFE
81
181
SAFE2
90
190
Y90
91
191
Y91
93
193
Y93
95
195
Y95
96
196
REM
98
198
LF
99
199
ALM
9999
∗1
Note that when the frequency setting is varied using an analog signal or
alternate ON and OFF depending on that varying speed and the timing of the varying speed due to acceleration/deceleration time setting.
(The output will not alternate ON and OFF when the acceleration/deceleration time setting is "0s".)
∗2
These parameters can be set only in the safety stop function model.
REMARKS
The same function may be set to more than one terminal.
When the function is executed, the terminal conducts at the setting of any of "0 to 99", and does not conduct at the setting of
any of "100 to 199".
NOTE
Changing the terminal assignment using Pr.190 to Pr.192 (output terminal function selection) may affect the other
functions. Set parameters after confirming the function of each terminal.
Do not assign signals which repeat frequent ON/OFF to terminal A, B, C. Otherwise, the life of the relay contact
decreases.
146
Function
During retry
Output during retry processing.
The signal is output while the main circuit power supply is
24V external power
off and the 24V power is supplied externally. This signal is
supply operation ∗2
available when FR-E7DS is mounted.
Safety monitor output
Output while safety stop function is activated.
∗2
Safety monitor output 2
The signal is output when no internal safety circuit failure
∗2
(E.SAF, E.6, E.7, E.CPU) exists.
Output when any of the control circuit capacitor, main
Life alarm
circuit capacitor and inrush current limit circuit or the
cooling fan approaches the end of its service life.
Fault output 3
Output when a fault occurs due to the internal circuit failure
(power-off signal)
of the inverter wiring mistake.
Average current value and maintenance timer value are
Current average value
output as pulses.
monitor signal
The signal can not be set in Pr. 192 A,B,C terminal function
selection .
Maintenance timer
Output when Pr. 503 rises to or above the Pr. 504 setting.
signal
Remote output
Output to the terminal when a value is set to the parameter.
Output when an alarm (fan failure or communication error
Alarm output
warning) occurs.
Output when the fault occurs.
Fault output
The signal output is stopped when the fault is reset.
No function
Operation
of the operation panel, the output of the SU (up to frequency) signal may
Refer
Related
to
Parameter
Page
Pr. 65 to
170
Pr. 69
31
31
Pr. 255 to
264
Pr. 259
148
Pr. 555 to
269
Pr. 557
Pr. 503,
268
Pr. 504
Pr. 495 to
152
Pr. 497
Pr. 121,
214,
Pr. 244
263
148