7-5. Protection Level Setting
In this setting mode, listed below items can be selected.
Parameter Item
Trip Level
Over voltage stage 1
Trip Time
Over voltage stage 1
Trip Level
Over voltage stage 2
Trip Time
Over voltage stage 2
Trip Level
Under voltage stage
Trip Time
Under voltage stage
Trip Level
Over frequency
Trip Time
Over frequency
Trip Level
Under frequency
Trip Time
Under frequency
Vnom_max
fstop
fstop-CH
Table Protection Level Setting List
Parameter Item
Display
Default Set
Point
Australia
Range
230.0V ∼
260.0V
260.0V
1.0s ∼
2.0s
2.0s
260.0V ∼
265.0V
265.0V
Setting
0.2s
Disable
180.0V ∼
180.0V
230.0V
1.0s ∼
2.0s
2.0s
50.00Hz ∼
52.00Hz
52.00Hz
Setting
0.2s
Disable
47.00Hz ∼
47.00Hz
50.00Hz
1.0s ∼
2.0s
2.0s
244.0V ∼
255.0V
258.0V
51.00Hz ∼
52.00Hz
52.00Hz
47.00Hz ∼
49.00Hz
49.00Hz
New Zealand
Default Set
Range
Point
230.0V ∼
260.0V
260.0V
1.0s ∼
2.0s
2.0s
260.0V ∼
265.0V
265.0V
Setting
0.2s
Disable
180.0V ∼
180.0V
230.0V
1.0s ∼
2.0s
2.0s
50.00Hz ∼
52.00Hz
52.00Hz
Setting
0.2s
Disable
45.00Hz ∼
45.00Hz
50.00Hz
1.0s ∼
2.0s
2.0s
244.0V ∼
248.0V
258.0V
51.00Hz ∼
52.00Hz
52.00Hz
47.00Hz ∼
49.00Hz
49.00Hz
71

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lj-sbk01Lj-na02

Table of Contents