Lithium-ion storage battery system
Hide thumbs Also See for LJ-SK56A:
Table of Contents

Advertisement

1-2 Off-line System
Off-line system has three operation modes determined by the way the storage battery is used, the maximum self-
consumption mode, programmed charge/discharge time mode, and Back-up mode. Select an operation mode to
use the storage battery system. See 8-2 to see how to select.
* If you are a user of the on-line system, the off-line system operates when the programs are not issuing control
commands. The operation mode needs to be set.
* In order to correct the remaining battery level, charging and discharging operation are stopped once a day (From 3:00 to 3:30),
except in the back-up mode operation.
Maximum Self-consumption Mode
• The product works in harmony with PV generation.
• By storing excess electricity in the product during the day, clean energy can be used around the clock even after
the sun goes down. This allows not only for the maximum utilization of clean energy, but also reduces the user's
electricity bills.
* Energy is not sold to the utility while the product is discharging.
Programmed Charge/Discharge Time Mode
• The customer can set the charge or discharge time on the product directly. The battery will be charged or
discharged only during this designated time. At other times it will not be charged or discharged.
* Energy is not sold to the utility while the storage battery is discharging.
* Set the charging/discharging duration. See 8-4 to see how to set it.
Back-up Mode
• Always charge the storage battery until it is fully charged, after it has been completely charged it is in standby in
preparation for a power failure.
1-3 Stand-alone Operation
When power fails, the product can supply electrical power to the Stand-alone socket.
* Switch the operation mode manually to stand-alone operation when power fails. Switch the operation mode manually to grid
operation when the power comes back on. For details, see Chapter 5.
* Stand-alone operating time is dependent on the "battery remaining" and "connected load". See Chapter 8-3.
NOTICE:
* This is not an UPS (Uninterruptible Power Supply).
* The degree of deterioration and the remaining amount of
* Stand-alone socket can not be used during Grid Operation.
* The amount of electricity that can be used in stand-alone socket is the maximum 2kVA.
* If maximum power
supply in stand-alone socket is more than 2kVA, power supply will stop.
* The low power factor and high output distortion ratio equipment will not work.
* Power supplied from this product is not completely same as the commercial power supply.
* When the battery remaining level reaches zero, the "Stand-alone" operation will automatically stop.
The operating state of dimming lights may differ in the case of operating in grid mode and in the case of operating in stand-alone
mode.
The following equipments are supposed to be connected to the Stand-alone socket.
* LED light bulb/Florescent desk lamp/Incandescent lamp
* Modem
* Router
* Cellular telephony/Smart phone/Tablet computer
* Portable TV/Radio
* Electric kettle
※When you connect one of the Electric kettle to Stand-alone Socket-outlet, the power consumption of the Electric kettle is
less than or equal to 2kW. When connecting a plurality of load, the sum of the load is to use the power consumption of the
Electric kettle of less than or equal to 2kW.
And the power output is stopped from the Stand-alone Socket-outlet because of a reduction of the remaining battery level,
there is a possibility that can not boil water completely in the Electric kettle.
battery influence
power supply time.