Changing The Management Vlan - ZyXEL Communications IES4005M User Manual

2u 5-slot temperature-hardened chassis msan
Table of Contents

Advertisement

Chapter 10 Initial Setup
The mask is a number from 1 to 31.
This example changes the inband management IP address to 172.1.1.10 with subnet mask
255.255.255.0 (/24).
ras# configure
ras(config)# ip inband address 172.1.1.10 24
This example changes the out-of-band management IP address (for local access) to 172.1.1.10
with subnet mask 255.255.255.0.
ras# configure
ras(config)# ip outband address 172.1.1.10/24
Note: Afterwards, you have to use the new IP address to access the IES.

10.4 Changing the Management VLAN

This command changes the inband management VLAN IP.
ip inband mgmt-vlan <mgmt-vid>
Note: After the following example configuration, you must connect through a VLAN aware
device using the proper VLAN ID in order to perform management.
This example sets the VLAN ID 3 for managing the system (the "management" or "CPU" VLAN).
ip inband mgmt-vlan 3
Note: Remote access could be affected.