ZyXEL Communications IES4005M User Manual page 172

2u 5-slot temperature-hardened chassis msan
Table of Contents

Advertisement

Chapter 24 VDSL
Table 116 VDSL Commands Summary (continued)
COMMAND
max-nor-atp-us <tx-power>
max-arp-us <rx-power>
pm-mode allow-l3|allow-
l2|allow-both
no pm-mode
pm-parameters <l0-time> <l2-
time> <l2-power-down-step>
<l2-power-down-max>
rfiband <start-carrier> <end-
carrier> [<start-carrier>
<end-carrier> ...]
no rfiband
bitswap-ds inactive
bitswap-us inactive
no bitswap-ds inactive
no bitswap-us inactive
snr-mode-ds
snr-mode-us
no snr-mode-ds
no snr-mode-us
refvn-ds <carrier-index> <vn-
psd> [<carrier-index> <vn-
psd> ...]
172
DESCRIPTION
Configures the upstream maximum nominal aggregation transmit
power.
tx-power: 0-255 in step of 0.1 dB, default: 130
Configures the upstream maximum aggregation receive power.
rx-power: -255-255 in step of 0.1dB, default: 130
Configures the power management operating mode (used for
ADSL2 and ADSL2+ protocol).
: Allows the DSL line to autonomously change to idle
allow-l3
(L3) state.
: Allows the DSL line to autonomously change to low
allow-l2
power (L2) state.
: Allows the DSL line to autonomously change to idle
allow-both
(L3) state and low power (L2) state.
Disables power management (used for ADSL2 and ADSL2+
protocol).
Sets the L0 (full power) and L2 (low power) power mode transition
settings (used for ADSL2 and ADSL2+ protocol).
l0-time: Time (0-255 seconds) to stay in L0 mode.
l2-time: Time (0-255 seconds) to wait before performing another
power trim in L2 mode.
l2-power-down-step: Maximum total aggregate power reduction
in dB (0-15) per power trim in L2 mode, default: 1
l2-power-down-max: Maximum total aggregate power reduction
in dB (0-15) in L2 mode, default: 6
Configures and enables Notch Frequency Interference (RFI)
bands.
start-carrier: 0-4096
end-carrier: 0-4096
Disables Notch Frequency Interference (RFI) bands.
Disables downstream bit swap.
Disables upstream bit swap.
Enables downstream bit swap.
Enables upstream bit swap.
Enables downstream virtual noise (used for VDSL2 protocol).
Enables upstream virtual noise (used for VDSL2 protocol).
Disables downstream virtual noise (used for VDSL2 protocol).
Disables upstream virtual noise (used for VDSL2 protocol).
Configures the downstream virtual noise PSD level by defining the
break points (used for VDSL2 protocol).
carrier-index: 0-4095
vn-psd: 0-200 or 255. 0 = -140dBm/Hz,-200 = -40 dBm/Hz in
steps of 0.5 dBm/Hz, 255 = 0 W/Hz