The following table describes the Ethernet cable's pin layout for the ALARM port connection.
Table 39 Ethernet ALARM Cable PIN Layout
PIN NO.
1
2
3
4
5
6
7
8

7.5.4 Specifications

The following table lists the specifications of the Ethernet LAN cables.
Table 40 Local Management Cable Specifications
ITEM
Connectors (X1/X2)
Type
Number of wires
7.6 RJ-45 DB-9 Cable
The CONSOLE2 connector is for communicating with a UPS. When you deploy the IES with a UPS,
only the POTS modules function during a power outage so subscribers can still make emergency
calls.

7.6.1 Application

The connections are as follows:
• The RJ-45 connector connects to the CONSOLE2 port.
• The DB-9 socket labeled MB connects to a UPS.

7.6.2 Appearance

The following figure shows a one RJ-45 to two DB-9 cable. Connect the DB-9 connector labeled MB
to a UPS. At the time of writing, the MSC1002G does not use the other DB-9 connector (labeled
DB).
IES4005M User's Guide
TIP COLOR
White and orange
Orange
White and green
Blue
White and blue
Green
White and brown
Brown
DESCRIPTION
RJ-45 male
Category-5 unshielded twisted pairs (UTP-5) or shielded twisted pairs (STP)
8
FUNCTION
Alarm Input 1, normal close
Alarm Input 1, common (FG)
Alarm Input 2, normal close
Alarm Input 3, normal close
Alarm Input 3, common (FG)
Alarm Input 2, common (FG)
Alarm Input 4, normal close
Alarm Input 4, common (FG)
Chapter 7 Cables
53