Chapter 56 IEEE 802.1Q Tagged VLAN and Isolation Commands

56.3.6 VLAN CPU Show Command Example

The following example sets VLAN ID 2 to be the CPU (management) VLAN.
ras> switch vlan cpu set 2

56.3.7 VLAN CPU Set Command Example

The following example sets VLAN ID 2 to be the CPU (management) VLAN.
ras> switch vlan cpu set 2

56.3.8 Configuring Management VLAN Example

Note: After the following example configuration, you must connect to the first Ethernet
port through a VLAN aware device that is using the proper VLAN ID in order to
perform management.
By default, the IES's xDSL ports are members of the management VLAN (VID 1).
The following procedure shows you how to configure a tagged VLAN that limits
management access to just one Ethernet port.
Note: Use the console port to configure the IES if you misconfigure the management
VLAN and lock yourself out.
Use the switch vlan set command to configure a VLAN ID (VID 3 in this
1
example) for managing the IES (the "management" or "CPU" VLAN).
ras> switch vlan set 3 enet1:FT
Use the switch vlan1q vlan cpu command to set VID 3 as the management
2
VLAN.
ras> switch vlan cpu set 3