Sip Options - Samsung OfficeServ 7000 Series Programming Manual

Call server
Hide thumbs Also See for OfficeServ 7000 Series:
Table of Contents

Advertisement

[837] SIP OPTIONS

This MMC permits the adjustments of optional Session Initiation Protocol (SIP) trunk
parameters. The MCP supports SIP and H.323 on a per-call-per-port basis. The settings are
system wide.
When changing IP
When changing any IP address/value, listed below, three digits must be input for
each (octet) field. Example 192.168.1.10 input must be: 192 168 001 010
SIP Stack Configuration
No
Parameter
00
RE-TRANS.
T1
01
RE-TRANS.
T2
02
RE-TRANS.
T4
03
GENERAL
RING
04
INVITE RING
05
PROVISIONAL
06
INV NO RESP
07
GEN NO
RESP
08
REQ RETRY
© SAMSUNG Electronics Co., Ltd.
OfficeServ 7000 Series Call Server Programming Manual
Description
The initial re-transmission time if there is no answer,
based on the RFC2543 specification. The range is
0~9900 ms.
The maximum re-transmission time if there is no answer,
based on the RFC2543 specification. The range is
0~9900 ms.
The time the User Agent Server waits after receiving the
ACK message. Based on the RFC2543 specification.
The range is 0~9900 ms.
The server retransmits the response for this length of
time until the requested retransmission is received.
For example, the wait time after sending 200 OK for
INFO. The range is 0~99900 ms.
After the client sends ACK for the INVITE Final Response, the
client cannot confirm if the server received the ACK message.
The client waits for this length of time after sending ACK
for the Final Response. The range is 0~99900 ms.
After receiving the Provision Response, the User Agent
waits for this length of time until Timeout ends. The range
is 0~999900 ms.
Before sending Cancel for the Invite Request, the User
Agent waits for this length of time. The range is 0~99900
ms.
Before sending Cancel for General Request, the User
Agent waits for this length of time. The range is 0~99900
ms.
After sending General Request, the User Agent waits for
the Final Response for this length of time. The range is
0~99900 ms.
Default
500 ms
4000 ms
5000 ms
5000 ms
5000 ms
180000 m
5000 ms
5000 ms
5000 ms
2-379

Advertisement

Table of Contents
loading

Table of Contents