CHAPTER 2. MMC Programming
No
Code
59
MJD08
60
MJD09
62
MJD11
63
MJD12
64
MJD13
65
MJD14
66
MJD15
67
MJD16
-
MJD--
69
MJD18
70
MJD19
71
MJD20
72
MJD21
73
MJD22
74
MJD23
75
MJD24
-
MJE--
76
MJE01
78
MJE03
79
MJE04
2-416
Alarm Name
Blue Alarm Rec
A blue alarm condition has been cleared.
Alarm Data=Cabinet, Slot (Cx-Syy)
Bit Error Alarm
Alarm is activated when the error rate exceeds 1 x 10
errors. Note: 1x10
threshold for major alarm errors on E1, PRI or BRI.
Alarm Data=Cabinet, Slot (Cx-Syy)
SPID Init Error
The BRI received an error from the network.
Alarm Data=Cabinet, Slot, Channel (Cx-Syy-czz)
SPID Init Rec
The BRI has recovered from an error on the network
Alarm Data = Cabinet, Slot, Channel (Cx-Syy-czz)
LPBK Error
Internal on demand loopback failed.
Alarm Data = Cabinet, Slot, Channel (Cx-Syy-czz)
LPBK Recovery
Internal on demand loopback test passed.
Alarm Data = Cabinet, Slot, Channel (Cx-Syy-czz)
BRI DL Unavail
A BRI data link is out of service.
Alarm Data = Cabinet, Slot, Channel (Cx-Syy-czz)
BRI DL Recovery
A BRI data link is back in service.
Alarm Data = Cabinet, Slot, Channel (Cx-Syy-czz)
DTRK Error
ISDN or E1 card Fault
E1 Restart
The E1 card has restarted.
Alarm Data = Cabinet, Slot (Cx-Syy)
PRI Restart
The PRI card has restarted.
Alarm Data = Cabinet, Slot (Cx-Syy)
BRI Restart
The BRI card has restarted.
Alarm Data = Cabinet, Slot (Cx-Syy)
PCM Loss
Loss of PCM coding on a digital facility.
Alarm Data = Cabinet, Slot (Cx-Syy)
PCM Recovery
Loss of PCM coding on a digital facility.
Alarm Data = Cabinet, Slot (Cx-Syy)
L2 Disconnect
PRI L2 sync alarm
L2 Connect
PRI L2 sync alarm
MGI Error
MGI card Fault
MGI Restart
The MGI card has restarted.
Alarm Data = Cabinet, Slot (Cx-Syy)
MGI IP Duplicate
The MGI card IP address is duplicated.
Alarm Data = Cabinet, Slot (Cx-Syy)
MGI NTWK Error
The MGI card has blocked because the system detects
the card doesn't respond via network link.
External ping test.
Alarm Data = Cabinet, Slot (Cx-Syy)
Definition
-6
is threshold for minor alarm, 1 x 10
© SAMSUNG Electronics Co., Ltd.
(Continued)
-6
-3
is