Chapter 3
Assembling and Mounting a Cisco TelePresence System 1100
Figure 3-1
CTS 1100 Wall Requirements
Display Mount Installation Location
1/2" minimum
Drywall Thickness
(Both Sides of Stud)
OL-19695-01
16" or 24" (on center) Studs
(Must be centered on stud)
Front
Drywall
Steel Stud (2 x 4 / 25ga minimum)
Stud type and structural strength must conform to the North American
Specification for the Design of Cold-Formed Steel Structural Members.
[362 S 125 18, C-Shaped, S-Stud Section]
Cisco TelePresence System 1100 Assembly, First-Time Setup, and Field Replaceable Unit Guide
If back side of wall is unfinished, drywall must be installed
to a minimum of one stud left and right of the stud(s)
being used to install the mount. Drywall must be
secured to studs with screws 12" on center
Important Warnings and Cautions
There must be a minimum of
2 1/4 inches (57mm)
clearance inside wall
3-3