Troubleshooting; Basic Troubleshooting; Troubleshooting Digital Extensions - NEC ux5000 Hardware Manual

Hide thumbs Also See for ux5000:
Table of Contents

Advertisement

Chapter 3 - Installing Extensions and Trunks
S
3-14
ECTION

TROUBLESHOOTING

3.14.1

Basic Troubleshooting

3.14.1.1

Troubleshooting Digital Extensions

Verify the ESIU blade
is functioning.
Status LED on
the ESIU blade
flashing green?
Verify whether a digital
keyset works.
Connect a test
terminal to a port
using another
modular jack. Does
the terminal work?
Verify the wiring
between the chassis
and the keyset.
Verify the connection
to the EXIFU if two
chassis are used.
Connect the terminal
directly to the
connector on the
ESIU. Does it work?
Connect another
terminal to the
same port on the
ESIU. Does it work?
The terminal may
3 - 24
Start
until LED status changes and recheck.
Is the Live
No
Yes
Yes
No
Yes
No
programming for the
extension. Refer to
No
the UX5000 Software
Manual if necessary.
Yes
The ESIU blade may
need repair.
Figure 3-14: Digital Extension Troubleshooting
If the Busy LED (red) is also
on, the blade is initializing. Wait
On
Is the Live
Status LED solid
green, flashing
or off?
Flashing
Main equipment
(chassis/CCPU) may
need repair.
Redo the wires between
the main equipment and
the modular jack.
* If it still does not work,
replace the cable(s) and/
or connectors.
No
Main equipment
(chassis/CCPU) may
need repair.
* If it still does not work,
replace the cable(s) and/
or connectors.
Redo the wires between
the main equipment and
the terminal.
Check system
No
need repair.
In Program 90-05, release the
Block on the blade and
Off
recheck the terminal operation.
Does the terminal
work?
Yes
Stop
No
Remove the blade and
insert another ESIU
blade into the same slot.
Does it work?
Yes
The ESIU blade may
need repair.
Connect the terminal directly to
the connector on the ESIU.
Does it work?
Yes
Stop
Chapter 3

Advertisement

Table of Contents
loading

Table of Contents