FULL DUPLEX SETTING

4.10.1

Full Duplex Setting for Terminals

Full-duplex mode for conversations allows both parties to talk and be heard simultaneously. All of the
UX5000 IP terminals are full-duplex and this cannot be changed. The UX5000 digital keysets are full-duplex
by default - except the 6-Button or 2-Button terminals which are half-duplex). If required, this setting can be
changed on the digital terminals to half-duplex mode. The following installation instructions can be used for
the Enhanced 12-Button or 24-Button, or DESI-Less terminals.
4.10.2

Programming the Digital Terminal for the Full Duplex

1. With the Enhanced 12-Button or 24-Button, or DESI-Less terminal not plugged in and the handset on-
hook, press the "4" and "6" buttons on the dial pad and connect the terminal cables.
This places the terminal into Service Class R/W mode. The MW LED will not be lit.
2. Press "8" to enter the Full Duplex (FDS) mode.
3. Push "1" to set to off or "2" to set to on.
4. Save to memory by pressing line key 2, 8, 14, or 20. The display changes back to the Service Class R/W
mode.
5. Lift the handset momentarily and hang it back up to return the terminal to idle condition.