Chapter 6 - Specifications and Parts List
Device
CCPU to Printer:
LAN Equipment
(IP Terminal, Hub,
GBA Adapter, etc.)
*CAT 5 recommended with GBA Adapter.
DID Trunks:
Tie Line Trunks:
2/4BRIU to ISDN
Terminals:
1PRIU to ISDN
Terminal:
ISDN Terminal:
6 - 36
UX5000 Cable Requirements
Cable Type
LAN
10Base-T: 4-wire
UTP
100Base-TX: 8-wire
10Base-T/
100Base-
TX
LAN
LAN (UTP) cable with
(UTP)
CAT3 or more for
CAT3 or
10Base-T, and CAT5 or
CAT 5
more for 100 Base-TX
CAT5
CAT5
2-wire 26 AWG
2-wire 24 AWG
2-wire 22 AWG
CAT5
4-wire 24 AWG
CAT5
4-wire 24 AWG
CAT5
4-wire 24 AWG
Cable Run Length (ft)
328
328.08 (100 meters)
Analog DID = 2,500
ohms
OPX = 1,500 ohms
13,123
20,997
34,777
Point-Multipoint short
connection: 329
Point-Multipoint long
connection: 984
Point-Point connection:
164-0
164
Point-Multipoint Short
Connection: 328
Point-Multipoint
Extension: 984
Point-Point: 1640
Notes
Regardless of whether it
receives power from the
AC adapter or switching
hub.
Includes SLT or exchange
Limitation depends on the
connecting Router,
Multiplexer or Exchange. If
the UX5000 is connected
to another UX5000
directly, up to 1,500 ohms
loop resistance (including
system).
From chassis to IP
terminal and within 328'.