Chapter 3 - Installing Extensions and Trunks
Installing 4-wire/8-lead Tie Lines:
1.
Punch down four pair cross-connect leads for each tie line on the CPE (customer) side of the RJ21X.
2.
Punch down the other end of the cross-connect to the line (A) block leads (in groups of 4 tie lines).
3.
Make sure the UX5000 is programmed correctly for 4-wire (Program 10-03-02) and the type is selected
(Program 10-03-03) for Type I or V.
4.
Punch down a 25-pair cable to the opposite side of the line (A) block.
5.
Plug in the corresponding RJ-61 connector to the 4TLIU blade connector.
6.
Install bridging clips on the A block. Label cross-connect blocks A2, A3, etc.
3 - 20
RJ61 Cable Connector - 4-Wire E&M, CN1A - CN1D
Pin No.
1
2
3
4
12345678
5
6
7
8
Connection
Description
-
Not Used
M
Control signal to trunk
R
Voice signal to trunk
R1
Voice signal from trunk
T1
Voice signal from trunk
T
Voice signal to trunk
E
Control signal from
trunk
-
Not Used