Avaya CS7000 Administrator's Manual page 213

9.4 suite release
Hide thumbs Also See for CS7000:
Table of Contents

Advertisement

Table 67
describes the parameters.
Table 67: Configuration Parameters
Parameter
Port
Clients
Protocol
[SMPP]
Logon
Password
IP
Port
TON
NPI
CS7000 System Administrator Guide for Release 9.4
Description
The port of the listening socket opened by the
SMS Controller. The connected client
applications must be configured to use the
same port number.
Specifies the maximum number of clients that
can connect to the SMS Controller.
This can be configured for SMPP or HTTP. It
describes the protocol used to communicate
with the SMSC. If the SMPP protocol is
selected here, the HTTP configuration settings
(URLA, URLB) are ignored. If the HTTP
protocol is selected here, the SMPP
configuration settings, Logon, Password,
Sender, IP, Port, Ton, NPI, are ignored.
The Short Message Peer to Peer (SMPP)
protocol is an open industry standard
messaging protocol. SMPP simplifies the
integration of data applications with wireless
mobile networks. These mobile networks
include, GSM, Time Division Multiple Access
(TDMA), and Code Division Multiple Access
(CDMA). This protocol is widely deployed in the
mobile telecommunications industry.
The SMPP configuration items depend on the
SMSC or GSM modem software that is being
used. When an account is set up with an
SMSC, some or all of the SMPP configuration
settings are provided. In the case of a GSM
modem, consult the third party modem software
to configure the SMPP settings.
SMSC account name
SMSC security password
IP server address of SMSC
Listening port of SMSC
Set to 0
Set to 0
Configuring the SMS Controller
1 of 2
January 2006
213