Remove the Top Cover

Removing the top cover without properly powering down the server and
Caution -
disconnecting the AC power cords from the power supplies results in a chassis intrusion switch
failure. This failure causes the server to be immediately powered off. Any changes you make
to the memory riser or DIMM configurations will not be properly reflected in the service
processor's inventory until you replace the top cover.
Ensure that the AC power cords are disconnected from the server power
1.
supplies.
2.
Press the green button to release the top cover (panel 1).
3.
Slide the cover towards the rear of the server chassis about 0.5 inch (12 mm).
4.
Lift up and remove the top cover (panel 2).
Related Information
"Replace the Top Cover" on page 178
"Open and Remove the Airflow Cover" on page 56