Remove the SPM

Remove the SPM
Caution -
the motherboard assembly. You must disconnect the power cables from the server before
performing these procedures.
Caution -
sensitivity can cause the component to fail. To avoid damage, ensure that you follow antistatic
practices as described in
You can perform this cold-service procedure. The server must be completely powered down
before performing this procedure. See
information about this category of service procedures.
The amber SP OK/Fault LED on the front panel will be lit when an SPM fault is detected.
1.
If possible, back up the Oracle ILOM configuration before removing the SPM.
After you replace the SPM, restoring the SPM configuration will be easier if you previously
saved the configuration using the Oracle ILOM backup utility. Refer to the Oracle ILOM
documentation for instructions on backing up and restoring the Oracle ILOM configuration.
To retain the same version of the system firmware with the new SPM, note the current version
before removing the SPM.
2.
Prepare for servicing.
a.
Attach an antistatic wrist strap.
b.
Power off the server and unplug power cords from the power supplies.
See
c.
Remove the server from the rack.
See
d.
Remove the top cover.
See
132
SPARC T7-1 Server Service Manual • May 2017
Ensure that all power is removed from the server before removing or installing
These procedures require that you handle components that are sensitive to ESD. This
"ESD Measures" on page
"Removing Power From the Server" on page
"Remove the Server From the Rack" on page
"Remove the Top Cover" on page
42.
"Component Service Categories" on page 45
46.
54.
55.
for more