Oracle SPARC T7-1 Service Manual page 162

Single- socket server for enterprise computing
Hide thumbs Also See for SPARC T7-1:
Table of Contents

Advertisement

Reactivate RAID Volumes
See
"Power On the Server (Oracle ILOM)" on page 180
Power Button)" on page
4.
At the OpenBoot prompt, list the device paths on the server.
ok show-devs
...
/pci@301/pci@2/scsi@0/disk@p0
...
You can also use the devalias command to locate device paths specific to your server.
ok devalias
...
scsi0
scsi
...
5.
Choose the RAID module on the motherboard.
ok select scsi
Instead of using the alias name scsi, you could type the full device path name (such as
/pci@301/pci@2/scsi@0).
6.
List all connected logical RAID volumes to determine which volumes are in an
inactive state.
ok show-volumes
For example, the following output shows an inactive volume:
ok show-volumes
Volume 0 Target 389 Type RAID1 (Mirroring)
WWID 03b2999bca4dc677
Optimal Enabled Inactive
2 Members
Disk 1
Primary Optimal
Target 9
Disk 0
Secondary Optimal
Target c
For each RAID volume listed as inactive, type the following command to activate
7.
that volume.
ok inactive_volume activate-volume
162
SPARC T7-1 Server Service Manual • May 2017
181.
/pci@301/pci@2/scsi@0
/pci@301/pci@2/scsi@0
583983104 Blocks, 298 GB
HITACHI H103030SCSUN300G A2A8
HITACHI H103030SCSUN300G A2A8
or
"Power On the Server (System