1.
At the Oracle ILOM prompt, type:
-> show disabled
Target
-----------------------------------+----------------+--------------------
...
/SYS/MB/CM0/CMP | disable_reason | Configuration Rules
...
2.
For additional information about a disabled component, type the show -t
command and the Oracle ILOM target.
See
"Component Names Displayed by Diagnostic Software " on page
For example:
-> show -t /SYS/MB/CM/CMP/BOB21/CH1/DIMM
Target
-----------------------------------+------------------------+------------
...
/SYS/MB/CM/CMP/BOB21/CH1/DIMM | type
/SYS/MB/CM/CMP/BOB21/CH1/DIMM | ipmi name
/SYS/MB/CM/CMP/BOB21/CH1/DIMM | requested_config_state | Enabled
/SYS/MB/CM/CMP/BOB21/CH1/DIMM | current_config_state
/SYS/MB/CM/CMP/BOB21/CH1/DIMM | disable_reason
/SYS/MB/CM/CMP/BOB21/CH1/DIMM | fru_name
...
Related Information
"Log In to Oracle ILOM (Service)" on page 24
■
"Identify Faulted Components" on page 24
■
"Component Names Displayed by Diagnostic Software " on page 27
■
Component Names Displayed by Diagnostic
Software
Use the information in this table to identify the name of a component that requires service.
Component
Battery
DIMMs on motherboard
| Property
| Property
Oracle ILOM Target
/SYS/MB/BAT
/SYS/MB/CM/CMP/BOBn/CHn/DIMM0
Identify Disabled Components
| Value
27.
| Value
| DIMM
| P0/M3/B0/C1/D0
| Enabled
| Configuration Rules
| 8192MB DDR4 SDRAM DIMM
Links
"Servicing the Battery" on page 125
"Servicing Memory Risers and
DIMMs" on page 89
Detecting and Managing Faults
27
Need help?
Do you have a question about the SPARC T7-1 and is the answer not in the manual?
Questions and answers