Component Names Displayed By Diagnostic Software - Oracle SPARC T7-1 Service Manual

Single- socket server for enterprise computing
Hide thumbs Also See for SPARC T7-1:
Table of Contents

Advertisement

1.
At the Oracle ILOM prompt, type:
-> show disabled
Target
-----------------------------------+----------------+--------------------
...
/SYS/MB/CM0/CMP | disable_reason | Configuration Rules
...
2.
For additional information about a disabled component, type the show -t
command and the Oracle ILOM target.
See
"Component Names Displayed by Diagnostic Software " on page
For example:
-> show -t /SYS/MB/CM/CMP/BOB21/CH1/DIMM
Target
-----------------------------------+------------------------+------------
...
/SYS/MB/CM/CMP/BOB21/CH1/DIMM | type
/SYS/MB/CM/CMP/BOB21/CH1/DIMM | ipmi name
/SYS/MB/CM/CMP/BOB21/CH1/DIMM | requested_config_state | Enabled
/SYS/MB/CM/CMP/BOB21/CH1/DIMM | current_config_state
/SYS/MB/CM/CMP/BOB21/CH1/DIMM | disable_reason
/SYS/MB/CM/CMP/BOB21/CH1/DIMM | fru_name
...
Related Information
"Log In to Oracle ILOM (Service)" on page 24
"Identify Faulted Components" on page 24
"Component Names Displayed by Diagnostic Software " on page 27
Component Names Displayed by Diagnostic
Software
Use the information in this table to identify the name of a component that requires service.
Component
Battery
DIMMs on motherboard
| Property
| Property
Oracle ILOM Target
/SYS/MB/BAT
/SYS/MB/CM/CMP/BOBn/CHn/DIMM0
Identify Disabled Components
| Value
27.
| Value
| DIMM
| P0/M3/B0/C1/D0
| Enabled
| Configuration Rules
| 8192MB DDR4 SDRAM DIMM
Links
"Servicing the Battery" on page 125
"Servicing Memory Risers and
DIMMs" on page 89
Detecting and Managing Faults
27

Advertisement

Table of Contents
loading

Table of Contents