Remove the SPM
Remove the SPM
Replacing the SPM is a cold-service procedure that must be performed by qualified service
personnel. The server must be completely powered down before performing this procedure.
Caution -
motherboard assembly. You must disconnect the power cables from the server before
performing these procedures.
Caution -
discharge. Static discharges can cause the components to fail.
The amber SP Fault LED on the front panel will be lit when an SPM fault is detected.
Back up the Oracle ILOM configuration before removing the SPM.
1.
At the Oracle ILOM prompt, type:
-> cd /SP/config
-> dump -destination uritarget
where acceptable values for uri are: tftp, ftp, sftp, scp, http, https
and target is the location where you want to store the configuration information. For example:
-> dump -destination tftp://129.99.99.99/pathname
Prepare for servicing.
2.
See
"Preparing for Service" on page
3.
Locate the SPM.
See
"Internal Component Locations" on page
136
SPARC T7-2 Server Service Manual • July 2019
Ensure that all power is removed from the server before working with the
This procedure requires that you handle components that are sensitive to electrostatic
47.