Time At; Time Once - HP FlexFabric 7900 Series Command Reference Manual

Hide thumbs Also See for FlexFabric 7900 Series:
Table of Contents

Advertisement

# In IRF mode, set the low-temperature threshold for hotspot sensor 1 on the card in slot 1 on IRF
member device 1 to –10°C (14°F), the warning threshold to 70°C (158°F), and the alarming
threshold to 90°C (194°F).
<Sysname> system-view
[sysname] temperature-limit chassis 1 slot 1 hotspot 1 -10 70 90

time at

Use time at to specify an execution date and time for a non-periodic schedule.
Use undo time to delete the execution date and time configuration for a non-periodic schedule.
Syntax
time at time date
undo time
Default
No execution time or date is specified for a non-periodic schedule.
Views
Schedule view
Predefined user roles
network-admin
mdc-admin
Parameters
time: Specifies the schedule execution time in the hh:mm format, where hh is in the range of 0 to 23,
and mm is in the range of 0 to 59.
date: Specifies the schedule execution date in the MM/DD/YYYY or YYYY/MM/DD format. The
YYYY value is in the range of 2000 to 2035, the MM value is in the range of 1 to 12, and the value
range for DD depends on the month value.
Usage guidelines
The specified time (date plus time) must be later than the current system time.
The time at command, the time once command, and the time repeating command overwrite one
another. The most recently configured command takes effect.
Examples
# Configure the device to execute schedule saveconfig at 01:01 a.m. on May 11, 2015.
<Sysname> system-view
[Sysname] scheduler schedule saveconfig
[Sysname-schedule-saveconfig] time at 1:1 2015/05/11
Related commands
scheduler schedule

time once

Use time once to specify one or more execution days and the execution time for a non-periodic
schedule.
Use undo time to delete the execution day and time configuration for a non-periodic schedule.
253