Exception Filepath - HP FlexFabric 7900 Series Command Reference Manual

Hide thumbs Also See for FlexFabric 7900 Series:
Table of Contents

Advertisement

Usage guidelines
The device records its current startup software version information and all subsequent version
update information. Such information can survive reboots.
A maximum of 10 records can be saved.
Examples
# Display the startup software image upgrade history records.
<Sysname> display version-update-record
Name
Record 1
(updated on Aug 27 2015 at 10:32:37):
* 7900-CMW710-BOOT-R2150.bin
* 7900-CMW710-SYSTEM-R2150.bin
* 7900-CMW710-DEVKIT-R2150.bin
* 7900-CMW710-MANUFACTURE-R2150.bin
Table 42 Command output
Field
Name
*
Related commands
reset version-update-record

exception filepath

Use exception filepath to specify the directory for saving core files on an MPU.
Use undo exception filepath to remove the directory setting (set the directory to NULL) on an MPU.
Syntax
exception filepath directory
undo exception filepath directory
Default
The directory for saving core files is flash: on an MPU.
Views
User view
Predefined user roles
network-admin
mdc-admin
Parameters
directory: Specifies the root directory of a storage medium on an MPU.
Usage guidelines
The system will save core files to the core folder in the core file directory on the active MPU (in
standalone mode) or the global active MPU (in IRF mode).
If the core folder does not exist, the system creates the folder.
Version
7.1.045 Release 2150
7.1.045 Release 2150
7.1.045 Release 2150
7.1.045 Release 2150
Description
Software image file name.
The new software image is different from the old one.
231
Compile time
Aug 14 2015 16:33:12
Aug 14 2015 16:33:12
Aug 14 2015 16:33:12
Aug 14 2015 16:33:12

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents