When the temperature drops below the low-temperature threshold or reaches the high-temperature
warning threshold, the device performs the following tasks:
Logs the event.
Sends a log message.
Sends a trap.
When the temperature reaches the high-temperature alarming threshold, the device performs the
following tasks:
Logs the event.
Sends log messages repeatedly.
Sets the LEDs on the device panel.
When the temperature of an LPU or switching fabric module reaches the high-temperature shutdown
threshold, the device performs the following tasks:
Logs the event.
Sends a log message.
Shuts down the LPU.
The shutdown temperature thresholds are not configurable.
Examples
# In standalone mode, set the low-temperature threshold for hotspot sensor 1 on the card in slot 1 to
–10°C (14°F), the warning threshold to 70°C (158°F), and the alarming threshold to 90°C (194°F).
<Sysname> system-view
[sysname] temperature-limit slot 1 hotspot 1 -10 70 90
# In IRF mode, set the low-temperature threshold for hotspot sensor 1 on the card in slot 1 on IRF member
device 1 to –10°C (14°F), the warning threshold to 70°C (158°F), and the alarming threshold to 90°C
(194°F).
<Sysname> system-view
[sysname] temperature-limit chassis 1 slot 1 hotspot 1 -10 70 90

time at

Use time at to specify an execution date and time for a one-time schedule.
Use undo time to remove the execution time configuration for a schedule.
Syntax
time at time date
undo time
Default
No execution time or date is specified for a schedule.
Views
Schedule view
Predefined user roles