Display Device Manuinfo - HP FlexFabric 7900 Series Command Reference Manual

Hide thumbs Also See for FlexFabric 7900 Series:
Table of Contents

Advertisement

2/3
NONE
2/4
NONE
2/5
NONE
2/6
NONE
2/7
NONE
2/8
NONE
2/9
NONE
2/10
LSVM1SRPC1
2/11
NONE
The output shows that the IRF fabric has two member devices. The card in slot 10 on member device
1 is the global active MPU. The card in slot 10 on member device 2 is the global standby MPU.
Table 31 Command output
Field
Slot
Type
State
Subslot
Soft Ver
Patch Ver

display device manuinfo

Use display device manuinfo to display electronic label information for the device.
Syntax
In standalone mode:
display device manuinfo [ slot slot-number ]
In IRF mode:
display device manuinfo [ chassis chassis-number [ slot slot-number ] ]
Views
Any view
Predefined user roles
network-admin
network-operator
mdc-admin
mdc-operator
Absent
0
Absent
0
Absent
0
Absent
0
Absent
0
Absent
0
Absent
0
Standby
0
Absent
0
Description
Member ID of the device and slot number of the card.
Card type.
Card state:
Absent—No card is inserted in the slot.
Master—The card is the global active MPU.
Standby—The card is a global standby MPU.
Normal—The card is an interface card and is operating correctly.
Fault—The card is faulty and cannot start up.
Offline—The card is a switching fabric module and its forwarding plane is
in isolated state.
Maximum number of subcards that the card supports.
Software version of the card.
Patch version of the card. If no patch is installed, the value of this field is None.
206
NONE
NONE
NONE
NONE
NONE
NONE
NONE
7910-2150
NONE
None
None
None
None
None
None
None
None
None

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents