Pm[1]|2[:Deviation]; Pm[:Deviation]:Step[:Increment] - Keysight N5171B EXG Manual

X-series signal generators
Hide thumbs Also See for N5171B EXG:
Table of Contents

Advertisement

Analog Modulation Commands
Phase Modulation Subsystem–Option UNT ([:SOURce])

:PM[1]|2[:DEViation]

[:SOURce]:PM[1]|2[:DEViation] <value><unit>|UP|DOWN
[:SOURce]:PM[1]|2[:DEViation]?
This command sets the deviation of the phase modulation.
The variable <unit> will accept RAD (radians), PIRAD (pi-radians), and DEG
(degrees); however, the query will only return values in radians.

:PM[:DEViation]:STEP[:INCRement]

[:SOURce]:PM[:DEViation]:STEP[:INCRement] <value><unit>
[:SOURce]:PM[:DEViation]:STEP[:INCRement]?
This command sets the phase modulation deviation step increment.
Keysight EXG and MXG X-Series Signal Generators SCPI Command Reference
Supported
All Models with Option UNT
*RST
+0.00000000E+000
Range
See the Data Sheet for range values
Key Entry
ΦM Dev
Remarks
Refer to :PM[:DEViation]:STEP[:INCRement] command
for setting the value associated with the UP and DOWN
choices.
Supported
All Models with Option UNT
Range
0.001–1E3RAD
Key Entry
Incr Set
Remarks
The value set by this command is used with the UP and
DOWN choices for the FM deviation command.
Refer to :PM[1]|2[:DEViation] command for more
information.
The setting enabled by this command is not affected by
signal generator power-on, preset, or *RST.