System Commands
Route Subsystem (:ROUTe)
HARDware:DGENerator:INPut:DPOLarity
:ROUTe:HARDware:DGENerator:INPut:DPOLarity POSitive|NEGative
:ROUTe:HARDware:DGENerator:INPut:DPOLarity?
This command configures the polarity of the TTL input signal at the DATA
connector. POSitive refers to normal logic, while NEGative refers to inverted
logic.
HARDware:DGENerator:INPut:SPOLarity
:ROUTe:HARDware:DGENerator:INPut:SPOLarity POSitive|NEGative
:ROUTe:HARDware:DGENerator:INPut:SPOLarity?
This command configures the polarity of the TTL input signal at the SYMBOL
SYNC connector. POSitive refers to normal logic, while NEGative refers to
inverted logic.
HARDware:DGENerator:IPOLarity:BGATe
:ROUTe:HARDware:DGENerator:IPOLarity:BGATe POSitive|NEGative
:ROUTe:HARDware:DGENerator:IPOLarity:BGATe?
This command configures the polarity of the input signal at the BURST GATE IN
connector. POSitive refers to normal logic, while NEGative refers to inverted
logic.
Keysight EXG and MXG X-Series Signal Generators SCPI Command Reference
Remarks
This command performs the same function as
"HARDware:DGENerator:IPOLarity:CLOCk" on page
190.
Supported
N5172B with Option 653 or 655, N5182B with Option
656 or 657
*RST
POS
Key Entry
Data Polarity Neg Pos
Remarks
This command performs the same function as
"HARDware:DGENerator:IPOLarity:DATA" on page
Supported
N5172B with Option 653 or 655, N5182B with Option
656 or 657
*RST
POS
Key Entry
Symbol Sync Polarity Neg Pos
Remarks
This command performs the same function as
"HARDware:DGENerator:IPOLarity:SSYNc" on page
191.
Supported
N5172B with Option 653 or 655, N5182B with Option
656 or 657
190.