Arb Commands
Dual ARB Subsystem–N5172B/82B ([:SOURce]:RADio:ARB)
NOTE: All first-generation MXG slaves must be at the end of the
synchronization chain.
The NASLaves value is a persistent setting that survives both preset and power
cycling.
Example
:RAD:ARB:MBS:NASL 3
The preceding example enters three as the number of first-generation MXG
slaves the current signal generator master/slave setup.

:MBSync:NSLaves

[:SOURce]:RADio:ARB:MBSync:NSLaves <value>
[:SOURce]:RADio:ARB:MBSync:NSLaves?
This command enters the number of signal generators designated as slaves in
a multiple BBG synchronization setup. This value is required for both the
master and slave signal generators.
This command does not designate which slave position a signal generator
occupies. To set the slave position, see
The NASLaves value is a persistent setting that survives both preset and power
cycling.
Example
:RAD:ARB:MBS:NSL 7
The preceding example enters seven as the number of slaves the current signal
generator master/slave setup.

:MBSync:SLISten

[:SOURce]:RADio:ARB:MBSync:SLISten
For signal generators designated as slaves in the multiple BBG synchronization
setup, this command enables them to receive a one–time baseband
synchronization event trigger initiated by the master. The signal generator
receives the trigger signal through the PAT TRIG connector.
Keysight EXG and MXG X-Series Signal Generators SCPI Command Reference
Range
0 to 15 (depends on the NSLaves setting)
Key Entry
Number of MXG-A Slaves
Supported
N5172B/82B
Range
1 to 15
Key Entry
Number of Slaves
Supported
N5172B/82B
":MBSync:SREFerence" on page
358.