Scenario 2: Using Cisco Catalyst Switch 3650, Ons 15454, Ncs 2006, And Ncs - Cisco NCS 2006 Hardware Installation Manual

Ncs 2000 series
Table of Contents

Advertisement

Multishelf Management
The scenario is illustrated in the figure below.
Figure 237: NCS 2015, NCS 2006, and ONS 15454 SSCs Connected to NCS 2006 NC Using RJ-45 and SFP Ports
Scenario 2: Using Cisco Catalyst Switch 3650, ONS 15454, NCS 2006, and NCS 2015 SSCs Can
Be Connected To the NCS 2006 NC
1 Using a cross-over (CAT-5) LAN cable:
a Plug one connector into Port 1 of the active Catalyst 3560.
b Plug the other connector into the MSM port of the NC corresponding to the control card in Slot 1.
2 Using a cross-over (CAT-5) LAN cable:
a Plug one connector into Port 1 of the standby Catalyst 3560.
b Plug the other connector into the MSM port of the NC corresponding to Slot 8.
3 Using a cross-over (CAT-5) LAN cable, plug one connector into Port 23 of the active Catalyst 3560. Plug
the other end into Port 23 of the standby Catalyst 3560.
4 To connect all the SSCs to the Catalyst 3560 switches, use a cross-over (CAT-5) LAN cable.
a Plug one connector into:
b M-MSM-1 port of NCS 2015 SSC that corresponds to the control card in Slot 1
c MSM port of NCS 2006 SSC that corresponds to the control card in Slot 1.
Cisco NCS 2006 Node Controller, and ONS 15454, NCS 2006, and NCS 2015 Subtending Shelves
Cisco NCS 2000 Series Hardware Installation Guide