NTP-L65 Configure the MS-ISC-100T Card for a ONS 15454 Multishelf Node for Non-Default Public and Private VLAN
IDs
Required/As Needed
Onsite/Remote
Security Level
Procedure
Step 1
At the Cisco IOS command line interface (CLI) for the MS-ISC-100T card, enter the following spanning tree
commands:
Example:
Router(config)# bridge
public VLAN ID
protocol rstp
Router(config)# bridge
forward-time 5
Router(config)# bridge
public VLAN ID
max-age 10
Router(config)# bridge
private VLAN ID
protocol rstp
Router(config)# bridge
private VLAN ID
forward-time 5
Router(config)# bridge
private VLAN ID
max-age 10
Step 2
Enter the following commands to configure the ports DCN 1 and DCN 2:
Example:
(Router(config)#interface FastEthernet0
(Router(config-if)# no ip address
(Router(config-if)# no ip route-cache
(Router(config-if)# bridge-group
public VLAN ID
(Router(config)#interface FastEthernet1
(Router(config-if)# no ip address
(Router(config-if)# no ip route-cache
(Router(config-if)# bridge-group
public VLAN ID
Step 3
Enter the following commands to configure ports SSC 1 through SSC 7. Replace port with the port number
(2 to 8) and repeat for each port.
Example:
(Router(config)#interface FastEthernet
port
(Router(config-if)# no ip address
(Router(config-if)# no ip route-cache
(Router(config-if)# bridge-group
private VLAN ID
Step 4
Enter the following commands to configure port NC (port 9):
Cisco NCS 2000 Series Hardware Installation Guide