Installing the Air Flow Regulator
Procedure
Step 1
Install the ANSI 23-inch adapter plates on the horizontal air plenum.
Step 2
Align the screws to fix the adapter plates to the shelf. Insert the screws and tighten them to a torque value of
11.5 in-lb (1.3 N-m).
Step 3
Install the vertical air plenum to the right of the horizontal plenum.
Step 4
Install the wing head screws from the internal side of the horizontal plenum and tighten the screws to a torque
value of 11.5 in-lb (1.3 N-m).
Step 5
Install the vertical air plenum to the left of the horizontal air plenum. Follow step 4.
Figure 23: Pre-assembling the air plenums
DLP-L71 Installing Pre-assembled Air Plenums in ANSI 23-inch Configuration

Cisco NCS 2000 Series Hardware Installation Guide

39