Addition Of Control Functions For Primary Devices And The Use Of Binary Inputs And Outputs - ABB relion REF615 Applications Manual

Feeder protection and control relion 615 series
Hide thumbs Also See for relion REF615:
Table of Contents

Advertisement

1MRS756378 S
Function
IEC 61850
IEC 61850-9-2 LE
SMVRCV
sampled value
receiving (voltage
8)9)
sharing)
Other
Minimum pulse timer
TPGAPC
(2 pcs)
Minimum pulse timer
TPSGAPC
(2 pcs, second
resolution)
Minimum pulse timer
TPMGAPC
(2 pcs, minute
resolution)
Pulse timer (8 pcs)
PTGAPC
Time delay off (8 pcs)
TOFGAPC
Time delay on (8 pcs)
TONGAPC
Set-reset (8 pcs)
SRGAPC
Move (8 pcs)
MVGAPC
Generic control point
SPCGAPC
(16 pcs)
Analog value scaling
SCA4GAPC
(4 pcs)
Integer value move
MVI4GAPC
(4 pcs)
1, 2, ... = Number of included instances. The instances of a protection function represent the number of identical protection function blocks available in the
standard configuration.
() = optional
1) "Uo measured" is always used.
2) "Uo calculated" is always used.
3) One of the following can be ordered as an option: admittance-based E/F, wattmetric-based E/F or harmonics-based E/F.
4) "Io measured" is always used.
5) "IoB measured" is always used.
6) Master trip is included and connected to the corresponding HSO in the configuration only when the BIO0007 module is used. If additionally
the ARC option is selected, ARCSARC is connected in the configuration to the corresponding master trip input.
7) Power quality option includes current total demand distortion, voltage total harmonic distortion, voltage variation and voltage unbalance.
8) Available only with IEC 61850-9-2
9) Available only with COM0031...0037
3.1.1
REF615
Application Manual
A
B
C
4
4
4
1
1
1
1
1
1
2
2
2
4
4
4
4
4
4
4
4
4
2
2
2
2
2
2
4
4
4
1
1
1
Addition of control functions for primary devices and the use
of binary inputs and outputs
If extra control functions intended for controllable primary devices are added to the
configuration, additional binary inputs and/or outputs are needed to complement the
standard configuration.
If the number of inputs and/or outputs in a standard configuration is not sufficient, it
is possible either to modify the chosen IED standard configuration in order to release
some binary inputs or binary outputs which have originally been configured for other
purposes, or to integrate an external input/output module, for example RIO600, to the
IED.
The external I/O module's binary inputs and outputs can be used for the less time-
critical binary signals of the application. The integration enables releasing some
initially reserved binary inputs and outputs of the IED's standard configuration.
REF615 standard configurations
D
E
F
G
(1)
(1)
(1)
4
4
4
4
1
1
1
1
1
1
1
1
2
2
2
2
4
4
4
4
4
4
4
4
4
4
4
4
2
2
2
2
2
2
2
2
4
4
4
4
1
1
1
1
Section 3
H
J
K
L
(1)
(1)
(1)
(1)
4
4
4
4
1
1
1
1
1
1
1
1
2
2
2
2
4
4
4
4
4
4
4
4
4
4
4
4
2
2
2
2
2
2
2
2
4
4
4
4
1
1
1
1
N
(1)
4
1
1
2
4
4
4
2
2
4
1
41