Control interfaces
Programmable analog inputs
The control unit has two programmable analog inputs. Analog inputs can be
used for PID purpose or to read external sensor values. With analog inputs,
speed of the motor cannot be changed as motor speed control is always by
internal MPPT logic of ACQ80. For more information, see section
on page 42.
program
Settings
Parameter group
Programmable analog outputs
The control unit has two current (0...20 mA) analog outputs. Analog output 1
can be set as a voltage (0/2...10 V) or current (0/4...20 mA) output with
parameters. Analog output 2 always uses current. Each output can be filtered,
inverted and scaled.
Settings
Parameter group
Programmable digital inputs and outputs
The control unit has six digital inputs.
Digital input DI5 can be used as high frequency pulse input. The panel shows the
appropriate selection only.
Settings
Parameter groups
Programmable frequency input and output
Digital input DI5 can be configured as high frequency input. The panel shows
the appropriate selection only.
Settings
Parameter groups
(page 106).
Programmable relay outputs
The control unit has three relay outputs. The signal to be indicated by the
outputs can be selected by parameters.
(page 108).
12 Standard AI
(page 115).
13 Standard AO
10 Standard DI, RO
10 Standard DI, RO
(page 100).
(page 100) and
11 Standard DIO, FI, FO
Program features 41
MPPT control