ABB relion REF615 Applications Manual page 44

Feeder protection and control relion 615 series
Hide thumbs Also See for relion REF615:
Table of Contents

Advertisement

Section 3
REF615 standard configurations
Description
Directional and non-directional overcurrent and earth-fault protection, high-impedance restricted
earth-fault protection, voltage and frequency based protection and measurements, synchro-check and
circuit-breaker condition monitoring (optional power quality and fault locator)
Directional and non-directional overcurrent and earth-fault protection with multifrequency neutral
admittance, voltage, frequency and power based protection and measurements, and circuit-breaker
condition monitoring (sensor inputs, optional power quality, fault locator, interconnetion protection and
synchro-check with IEC 61850-9-2 LE)
Directional and non-directional overcurrent and earth-fault protection with multifrequency neutral
admittance, voltage, frequency and power based protection and measurements, high-impedance
differential protection, synchro-check and circuit-breaker condition monitoring (optional power quality,
fault locator and interconnection protection)
Table 10:
Supported functions
Function
IEC 61850
Protection
Three-phase non-
PHLPTOC
directional overcurrent
protection, low stage
Three-phase non-
PHHPTOC
directional overcurrent
protection, high stage
Three-phase non-
PHIPTOC
directional overcurrent
protection,
instantaneous stage
Three-phase
DPHLPDOC
directional overcurrent
protection, low stage
Three-phase
DPHHPDOC
directional overcurrent
protection, high stage
Non-directional earth-
EFLPTOC
fault protection, low
stage
Non-directional earth-
EFHPTOC
fault protection, high
stage
Non-directional earth-
EFIPTOC
fault protection,
instantaneous stage
Directional earth-fault
DEFLPDEF
protection, low stage
Directional earth-fault
DEFHPDEF
protection, high stage
Admittance-based
EFPADM
3)
earth-fault protection
Wattmetric-based
WPWDE
3)
earth-fault protection
Transient/intermittent
INTRPTEF
earth-fault protection
Harmonics-based
HAEFPTOC
earth-fault protection
3)
Non-directional (cross-
EFHPTOC
country) earth-fault
protection, using
calculated Io
Negative-sequence
NSPTOC
overcurrent protection
Table continues on next page
38
A
B
C
D
1
1
1
1
2
2
2
2
1
1
1
1
2
2
1
1
1
1
1)
1)
2
2
1)
1)
1
1
1)3)
1)3)
(3)
(3)
1)3)
1)3)
(3)
(3)
4)
4)
1
1
3)4)
3)4)
(1)
(1)
1
1
2
2
2
2
E
F
G
H
1
1
2
2
1
1
1
1
2
2
1
1
2
1
1
2
2
2)
2
1
1
2)
1
3)
3)
2)3)
(3)
(3)
(3)
3)
3)
2)3)
(3)
(3)
(3)
4)
4)
1
1
3)4)
(1)
1
1
1
2
2
2
2
1MRS756378 S
Std. conf.
K
L
N
J
K
L
N
1
2
2
1
1
1
1
1
1
1
2
1
2
2
1
1
1
1
2
2
2
1
1
1
1
1
2
1
2
2)
2
1
1
1
2)
1
3)
2)3)
3)
(3)
(3)
(3)
3)
2)3)
3)
(3)
(3)
(3)
4)
2)4)
4)
1
1
1
3)4)
3)4)
3)4)
(1)
(1)
(1)
1
1
2
2
2
2
REF615
Application Manual

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents