Lenovo CN4093 Application Manual page 194

10gb converged scalable switch
Hide thumbs Also See for CN4093:
Table of Contents

Advertisement

5. Configure ports on Switch A connecting to downstream VLAG switches C and D.
6. Configure ports on Switch B connecting to downstream switches E and F.
7. Configure ISL between switches C and D, and between E and F as shown in Step 1.
8. Configure the Switch G as shown in Step 2.
194
CN4093 Application Guide for N/OS 8.3
CN 4093(config)# vlan 20
CN 4093(config-vlan)# exit
CN 4093(config)# interface port 10,11
CN 4093(config-if)# switchport mode trunk
CN 4093(config-if)# lacp key 600
CN 4093(config-if)# lacp mode active
CN 4093(config-if)# exit
CN 4093(config)# vlag adminkey 600 enable
Repeat these steps on Switch B for ports connecting to downstream VLAG switch
C and D.
CN 4093(config)# vlan 30
CN 4093(config-vlan)# exit
CN 4093(config)# interface port 15-18
CN 4093(config-if)# switchport mode trunk
CN 4093(config-if)# lacp key 700
CN 4093(config-if)# lacp mode active
CN 4093(config-if)# exit

Advertisement

Table of Contents
loading