Ufp Configuration Examples; Example 1: Access Mode - Lenovo CN4093 Application Manual

10gb converged scalable switch
Hide thumbs Also See for CN4093:
Table of Contents

Advertisement

UFP Configuration Examples

Example 1: Access Mode

1. Turn on UFP.
2. Configure internal port as UFP.
3. Configure virtual port.
4. Configure vPort access mode.
5. Configure vPort default VLAN.
6. Specify QoS parameters for the vPort.
7. Enable vPort.
8. Configure PVID/Native VLAN for external port 1.
350
CN4093 Application Guide for N/OS 8.3
Following is an example configuration of UFP vPorts in access mode.
CN4093(config)# ufp enable
CN4093(config)# ufp port INTA1 enable
Warning: "Tagging/Trunk-mode" is enabled on UFP port INTA1
CN4093(config)# ufp port INTA1 vport 1
CN4093(config_ufp_vport)# network mode access
CN4093(config_ufp_vport)# network default-vlan 100
CN4093(config_ufp_vport)# qos bandwidth min 30
CN4093(config_ufp_vport)# qos bandwidth max 90
CN4093(config_ufp_vport)# enable
CN4093(config_ufp_vport)# exit
CN4093(config)# interface port EXT1
CN4093(config-if)# switchport mode access
CN4093(config-if)# switchport access vlan 100
(in percentage)