4. Add ports, LAGs and virtual pipes to their vNIC groups.
256
CN4093 Application Guide for N/OS 8.3
CN 4093(config)# vnic vnicgroup 1
CN 4093(vnic-group-config)# vlan 1000
CN 4093(vnic-group-config)# member INTA1.1
CN 4093(vnic-group-config)# member INTA2.1
CN 4093(vnic-group-config)# port INTA4
CN 4093(vnic-group-config)# port EXT1
CN 4093(vnic-group-config)# failover
CN 4093(vnic-group-config)# enable
CN 4093(vnic-group-config)# exit
CN 4093(config)# vnic vnicgroup 2
CN 4093(vnic-group-config)# vlan 1774
CN 4093(vnic-group-config)# member INTA1.2
CN 4093(vnic-group-config)# member INTA2.2
CN 4093(vnic-group-config)# member INTA3.2
vNIC 3.2 is not enabled.
Confirm enabling vNIC3.2 [y/n]: y
CN 4093(vnic-group-config)# port INTA5
CN 4093(vnic-group-config)# trunk 1
CN 4093(vnic-group-config)# failover
CN 4093(vnic-group-config)# enable
CN 4093(vnic-group-config)# exit
Once VLAN 1000 and 1774 are configured for vNIC groups, they will not be
available for regular configuration.
Note: vNICs are not supported simultaneously on the same switch ports as
VMready.
(Select vNIC group)
(Specify the VLAN)
(Add vNIC pipes to the group)
(Add non-vNIC port to the group)
(Add uplink port to the group
(Enable vNIC failover for the group)
(Enable the vNIC group)