Lenovo CN4093 Application Manual page 255

10gb converged scalable switch
Hide thumbs Also See for CN4093:
Table of Contents

Advertisement

1. Configure the external LAG to be used with vNIC group 2.
2. Enable the vNIC feature on the switch.
3. Configure the virtual pipes for the vNICs attached to each internal port:
© Copyright Lenovo 2015
CN 4093(config)# portchannel 1 port EXT3,EXT4 enable
CN 4093(config)# vnic enable
CN 4093(config)# vnic port INTA1 index 1
CN 4093(vnic-config)# enable
CN 4093(vnic-config)# bandwidth 60
CN 4093(vnic-config)# exit
CN 4093(config)# vnic port INTA1 index 2
CN 4093(vnic-config)# enable
CN 4093(vnic-config)# bandwidth 40
CN 4093(vnic-config)# exit
CN 4093(config)# vnic port INTA2 index 1
CN 4093(vnic-config)# enable
CN 4093(vnic-config)# exit
CN 4093(config)# vnic port INTA2 index 2
CN 4093(vnic-config)# enable
CN 4093(vnic-config)# exit
As a configuration shortcut, vNICs do not have to be explicitly enabled in this step.
When a vNIC is added to the vNIC group (in the next step), the switch will prompt
you to confirm automatically enabling the vNIC if it is not yet enabled (shown for
INT3.2).
Note: vNICs are not supported simultaneously on the same switch ports as
VMready.
(Select vNIC 1 on the port)
(Enable the vNIC pipe)
(Allow 60% egress bandwidth)
(Select vNIC 2 on the port)
(Enable the vNIC pipe)
(Allow 40% egress bandwidth)
(Select vNIC 1 on the port)
(Enable the vNIC pipe)
(Select vNIC 2 on the port)
(Enable the vNIC pipe)
Chapter 15: Virtual NICs
255