setting source 2)
4: Frequency setting source 1+Frequency setting
source 2
6: Frequency setting source 1 x Frequency setting
source 2
8: |Frequency setting source 1-Frequency setting
source 2
Notes:
Frequency setting source 1: It represent the frequency set based on P0.03 frequency setting source 1.
Frequency setting source 2: It represent the frequency set based on P 0.04 frequency setting source 2
The frequencies set based on frequency setting source 1 and the frequency setting source 2 is used as the final
set frequency after appropriate combination operation.
If "FC" function terminal is defined (see P3.01-P3.11), and the terminal function is enabled, then the result of
frequency setting combination 2 of P0.06 is actual set frequency; if the "FC" function terminal is not defined,
or it is defined, but the terminal function is disabled, then result of frequency setting combination 1 of P0.05
is the actual set frequency. Users can switch at will between the two different frequency setting combinations.
If the combination mode is 6,7, then the value set by frequency setting source 2 no longer represents
frequency, instead it will be used as the coefficient, and the absolute value is the final result we want.
P0.07 Run command mode selection
0: Keypad control
2: Terminal control 2 (STOP valid)
4: Serial communication 2 (STOP valid)
Note 1:
In keypad control mode, the user controls start and stop of the inverter directly through RUN, STOP keys on
the keypad.
In terminal control mode, the user needs to define multi-function input terminal first to realize the operation
functions of RUN, F/R, FWD, REV, HLD, etc. (see P3.01~ P3.11), and then the terminal controls the start
and stop of the inverter.
In serial communication control mode, the user connects the serial communication port to a PC or PLC. The
start, stop, positive and negative rotation of the inverter is controlled by the communication mode.
When STOP key is enabled, the user can stop the inverter with the STOP key on the keypad, which is used in
occasions of site emergency stop. When STOP key is disabled, the user can only stop the inverter through the
set control mode.
When P0.07 is set to 5, JOG and STOP keys on the keypad are disabled; when JOG key is disabled, the JOG
key on the keypad fails, the user can only enable inching running through terminal.
In keypad and terminal control modes, the communication read/write parameter operations are ignored.
P0.08 Keypad direction setting
0: Forward
Notes:
Pressing "FWD/REV" will switch the direction, and change the value of this parameter P0.08. But the
changed direction only takes effect currently.
Only by changing value of function code and pressing "ENTER" to save the value, keypad direction
setting will be saved permanently.
Direction priority: Terminal set is the highest, second is set by communication, keypad is the lowest. If the
high one is invalid, the lower priority will take effect.
93
Chapter 5 Detailed Function Introductions
source 2)
5: Frequency setting source 1-Frequency setting source 2
7: Frequency setting source 1÷Frequency setting source 2
9: Frequency setting source2 × (Maximum output
frequency+frequency setting source1)
÷Maximum output frequency
Setting range: 0~5 [0]
1: Terminal control 1 (STOP invalid)
3: Serial communication 1 (STOP invalid)
5: Terminal control 3 (STOP and JOG invalid)
Setting range: 0.1 [0]
1: Reverse