PA.04 Rating Current of Motor 1
Notes:
PA.01~PA.04 are used to set the parameters of the controlled motor 1. To ensure the control performance,
please do set relevant values correctly according to parameters on the motor nameplate.
The motor power should match that of the inverter. Generally, the motor power is allowed to be 20% lower
than that of the inverter or 10% higher; otherwise, the control performance would not be ensured.
PA.05 No-load Current I0 of Motor 1
PA.06 Stator Resistance R1of Motor 1
PA.07 Stator Leakage Inductance L1 of Motor
1
PA.08 Rotor Resistance R2 of Motor 1
PA.09 Mutual Inductive Impedance Lm of
Motor 1
PA.10 Magnetic Saturation Coefficient 1of
Motor 1
PA.11 Magnetic Saturation Coefficient 2 of
Motor 1
PA.12 Magnetic Saturation Coefficient3 of
Motor 1
PA.13 Magnetic Saturation Coefficient 4 of
Motor 1
PA.14 Magnetic Saturation Coefficient 5 of
Motor 1
Notes:
If the motor parameters are unknown, please refer to the PA.29 motor parameters setting instruction. If they are
known, please write them down for PA.05~PA.09 correspondingly.
The motor magnetic saturation coefficients will be set automatically in the time of self-setting and doesn't have to be
set by users.
PA.15Motor 2 pole number
PA.16Motor 2 rated power
PA.17Motor 2 rated speed
PA.18Motor 2 rated current
PA.19Motor 2 no-load current I0
PA.20Motor 2 stator resistance R1
PA.21Motor 2 stator leakage inductance L1
PA.22Motor 2 rotor resistance R2
PA.23Motor 2 mutual inductive reactance
Lm
PA.24 Motor 2 magnetic saturation
coefficient 1
PA.25 Motor 2 magnetic saturation
coefficient 2
PA.26 Motor 2 magnetic saturation
coefficient 3
PA.27 Motor 2 magnetic saturation
coefficient 4
PA.28 Motor 2 magnetic saturation
coefficient 5
Notes:
151
Chapter 5 Detailed Function Introductions
Setting range : 0.1~999.9A [Based on Motor Type]
Setting range: 0.1~999.9A [Depending on model]
Setting range:0.001~65.000Ω [Depending on model]
Setting range:0.1~2000.0mH [Depending on model]
Setting range:0.001~65.000Ω [Depending on model]
Setting range:0.1~2000.0mH [Depending on model]
Setting range:0.0%~100.0% [Depending on model]
Setting range:0.0%~100.0% [Depending on model]
Setting range:0.0%~100.0% [Depending on model]
Setting range:0.0%~100.0% [Depending on model]
Setting range:0.0%~100.0% [Depending on model]
Setting range:2~56 [4]
Setting range:0.4~999.9kW [Depending on model]
Setting range:0~24000r/min [Depending on model]
Setting range:0.1~999.9A [Depending on model]
Setting range:0.1~999.9A [Depending on model]
Setting range:0.001~65.000Ω [Depending on model]
Setting range:0.1~2000.0mH [Depending on model]
Setting range:0.001~65.000Ω [Depending on model]
Setting range:0.1~2000.0mH [Depending on model]
Setting range:0.0%~100.0% [Depending on model]
Setting range:0.0%~100.0% [Depending on model]
Setting range:0.0%~100.0% [Depending on model]
Setting range:0.0%~100.0% [Depending on model]
Setting range:0.0%~100.0% [Depending on model]