Alpha 6000S series User Manual page 51

Table of Contents

Advertisement

Chapter 4 Parameter Index
Functi
Parameter
on code
Maximum output
P0.10
frequency
Upper limit
P0.11
frequency source
Upper limit
P0.12
frequency
Offset of upper
P0.13
limit frequency
Rated voltage of
P0.14
motor
Lower frequency
P0.15
limit
Maximum output
P0.16
voltage
Knob adjusting
P0.17
rate
Acceleration
P0.18
time 1
Deceleration
P0.19
time 1
50
LCD display
Setting range
3004GB and below:
MAX [50.00Hz, upper limit
frequency, set frequency,
multi-stage frequency, jumping
Maximum
frequency] ~ 650.0Hz
frequency
35R5GB and above:
MAX [50.00Hz, upper limit
frequency, set frequency,
multi-stage frequency, jumping
frequency] ~ 400.0Hz
0: Digital setting
1: Terminal AI1
2: Terminal AI2
Upper limit
3: Terminal AI3 (reserve for
frequency source
3004GB and below models)
4: Pulse input
5: Communication setting
MAX [lower limit frequency,
Upper limit
jog frequency, UP/DN given
frequency
amplitude, sleep threshold] ~
maximum frequency
Offset of upper
0.00Hz~upper limit frequency
limit frequency
Rated voltage of
60~480V
motor
Lower frequency
0.00Hz~upper limit frequency
limit
Maximum output
60~480V
voltage
0: Digital knob integral
regulation
Knob adjusting
rate
(1~250)×(0.01Hz/1rpm)
Knob adjusting rate
Power ≤ 132kW
Acceleration
0.1~3600s
time 1
Power ≥ 160kW
1.0~3600s
Power ≤ 132kW
Deceleration
0.1~3600s
time 1
Power ≥ 160kW
1.0~3600s
MODB
Factory
Mod.
US
setting
address
50.00Hz
×
010A
0
010B
×
50.00Hz
010C
0.00Hz
010D
Rated
*
010E
voltage
0.00Hz
010F
Rated
0110
×
voltage
50
×
0111
22kW
and
below:
0112
6.0s
Others:
20.0s
22kW
and
below:
0113
6.0s
Others:
20.0s

Advertisement

Table of Contents
loading

This manual is also suitable for:

6000v series6700s series

Table of Contents