P3: Switching value I / O terminal control
This page is only for 3004GB and below models
Function
Parameter
code
Mode of terminal
P3.00
action
X1 terminal
P3.01
function
57
LCD display
0: Closing is active
Mode of
1: Open is active (normally
terminal action
0: NULL not defined
1: FWD Forward running
2: REV Reverse running
3: RUN
4: F / R rotation direction
5: HLD self-holding
6: RST reset
7: FC set frequency selection
8: FJOG Forward jog
9: RJOG Reverse jog
10: UP Go up
11: DOWN Go down
12: UP / DOWN reset
13: FRE Free stopping
14: Forced stopping (based on
15: Stopping process plus DC
16: Acceleration and
deceleration prohibition
17: Inverter run prohibition
18: S1 multi-stage speed 1
19: S2 multi-stage speed 2
X1 terminal
20: S3 multi-stage speed 3
function
21: S4 multi-stage speed 4
22: S5 multi-stage speed 5
23: S6 multi-stage speed 6
24: S7 multi-stage speed 7
25: Command to switch to
terminal control 2
26: SS1 multi-stage speed
27: SS2 multi-stage speed
28: SS3 multi-stage speed
29: SS4 multi-stage speed
30: T1 acceleration and
deceleration time 1
31: T2 acceleration and
deceleration time 2
32: T3 acceleration and
deceleration time 3
33: T4 acceleration and
34: TT1 acceleration and
35: TT2 acceleration and
36: Forced stopping normally
37: EH0 external fault
Setting range
open / normally closed is
unconstrained by this)
deceleration time of
abnormal stopping)
braking
deceleration time 4
deceleration time
deceleration time
closed
Chapter 4 Parameter Index
Factory
MODBUS
Modify
address
setting
0
0400
×
1
0401
×

Advertisement