Notes:
When PC.03 is set as 1, the output current will be displayed in the monitoring state and the unit is A. If it is
set as 0, the target will not be displayed.
PC.04 Frequency Setting (Hz Flickering)
0: non-displayed
Notes:
PC.04 can be set as 1. The monitoring target can be selected by pressing the button. When the target is
selected, the unit is indicated as Hz and is flickering. If P0.03 is set as 1, it can be set via the numbers on the
keypad and can be adjusted with the number knob. The user can adjust the set frequency with the number
knob. If P0.17 is set as 0, the adjustment rate can be adjusted from 0.01Hz to 0.1Hz, even to the maximum of
1Hz to realize the rapid increase or decrease of frequency by turning the knob continuously. Please refer to
P0.17 for details.
PC.05 Rotate speed (r/min)
PC.06Reference speed (r/min flashes)
0: : No display
Notes:
When PC.05 is set as 1, the operating rotating speed will be displayed in the monitoring state and the unit is
r/min. If it is set as 0, the target will not be displayed.
When PC.06 is set as 1, the set rotating speed will be displayed in the monitoring state and the unit is r/min
and is flickering.
If PC.06=1, when the user switches to PC.05 or PC.06 by pressing >>, the following will be displayed: if it is
the ordinary operation and P0.03 is set as 1 (set with the numbers on the keypad), the set rotating speed can
be adjusted on line and the corresponding frequency value will be saved to P0.02 after pressing ENTER; if it
is the PID operation, and P7.00 is set as 0, P7.03 is set as 0:PG or single-phase speed-measuring input, the
speed PID giving can be adjusted on line and be saved in P7.08 after pressing ENTER; if P7.03 is not 0:PG or
the single-phase speed-measuring input, it cannot be adjusted. PC.06 will be displayed during the on-line
adjustment. After adjustment is over, the target before adjustment will be displayed.
PC.07 Linear speed (m/s)
PC.08 Reference linear speed (m/s flashes)
0: No display
Notes:
When PC.07 is set as 1, the operation linear speed will be displayed in the monitoring state and the unit is m/s
(the indicator light m/s is on). If it is set as 0, the target will not be displayed.
When PC.08 is set as 1, the set linear speed will be displayed in the monitoring state and the unit is m/s (the
indicator light m/s is on and flickering) (the target cannot be adjusted on line).
PC.09 Output power
0: No display
Notes:
When PC.09 is set as 1, the output power (no unit is displayed) will be displayed in the monitoring state. If it
is set as 0, the target will not be displayed.
PC.10 Output torque (%)
0: No display
Notes:
If PC.10 is set to 1, output torque will be displayed with unit "%" in monitoring state. If PC.10 is set to 0,
output torque will not be displayed.
PC.11 Output voltage (V)
PC.12 Bus voltage (V)
155
Chapter 5 Detailed Function Introductions
Setting Range: 0, 1 [1]
1: displayed
Setting range: 0.1 [1]
Setting range: 0.1 [0]
1: display
Setting range:: 0.1 [0]
Setting range:: 0.1 [0]
1: Display
Setting range: 0.1 [0]
1: Display
Setting range: 0.1 [0]
1: Display
Setting range: 0.1 [0]
Setting range: 0.1 [0]