Alpha 6000S series User Manual page 108

Table of Contents

Advertisement

The inverter can set three jump frequency points, and the jump frequency bandwidth can overlap or nesting.
If overlapped, the range broadens. When all three jump frequency set to 0.00 Hz, the jump function will be
disabled.
P2.13 Multi-step frequency 1
P2.14 Multi-step frequency 2
P2.15 Multi-step frequency 3
P2.16 Multi-step frequency 4
P2.17 Multi-step frequency 5
P2.18 Multi-step frequency 6
P2.19 Multi-step frequency 7
P2.20 Multi-step frequency 8
P2. 21 Multi-step frequency 9
P2.22 Multi-step frequency 10
P2.23 Multi-step frequency 11
P2.24 Multi-step frequency 12
P2.25 Multi-step frequency 13
P2.26 Multi-step frequency 14
P2.27 Multi-step frequency 15
Notes:
Define Multi-step frequency respectively, which can be used in Multi-step speed running and simple PLC
running.
P2.28 Dec time 2
P2.29 Acc time 2
P2.30 Dec time 3
P2.31 Acc time 3
P2.32 Acc time 4
P2.33 Dec time 4
P2.34 Deceleration time during
abnormal stopping
Notes:
Define acceleration and deceleration time 2, 3, 4 respectively (acceleration and deceleration time is defined
by P0.18 and P0.19) Acceleration time and deceleration time during inverter operation are determined by
external terminal via parameters P3.01 ~ P3.11; if they are all disabled, then it is acceleration and deceleration
time 1. When the terminal option is forced outage or unusual stopping, perform according to deceleration
time of unusual stopping. Acceleration and deceleration time of program timing run and jog run is out of
control of external terminals, but is selected by the set parameters.
107
Chapter 5 Detailed Function Introductions
Figure. 5-2-5 Jump Frequency
Setting range: 0.00~Max frequency [5.00Hz]
Setting range: 0.00~Max frequency [8.00Hz]
Setting range: 0.00~Max frequency [10.00Hz]
Setting range: 0.00~Max frequency [15.00Hz]
Setting range: 0.00~Max frequency [18.00Hz]
Setting range: 0.00~Max frequency [20.00Hz]
Setting range: 0.00~Max frequency [25.00Hz]
Setting range: 0.00~Max frequency [28.00Hz]
Setting range: 0.00~Max frequency [30.00Hz]
Setting range: 0.00~Max frequency [35.00Hz]
Setting range: 0.00~Max frequency [38.00Hz]
Setting range: 0.00~Max frequency [40.00Hz]
Setting range: 0.00~Max frequency [45.00Hz]
Setting range: 0.00~Max frequency [48.00Hz]
Setting range: 0.00~Max frequency [50.00Hz]
Setting range : 0.1~3600s [6.0/20.0s]
Setting range : 0.1~3600s [6.0/20.0s]
Setting range : 0.1~3600s [6.0/20.0s]
Setting range : 0.1~3600s [6.0/20.0s]
Setting range : 0.1~3600s [6.0/20.0s]
Setting range : 0.1~3600s [6.0/20.0s]
Setting range : 0.1~3600s [3.0/10.0s]

Advertisement

Table of Contents
loading

This manual is also suitable for:

6000v series6700s series

Table of Contents