Chapter 2 Installation and Wiring
External controller
外部控制器
1
6
Near-end of shield
屏蔽线近端接地
line is grounded
Fig. 2-23 Connection diagram while using drain
electrode of internal + 24V power supply (control
NOTE: Remove the short jumper JP1 connecting PLC and 24V,
and connect PLC to COM
3) Use connection mode of source of an external power, as shown in Fig. 2-25 (control board) and Fig. 2-26
(extension board).
External controller
外部控制器
9 ~ 30V
+
-
1
6
COM
屏蔽线近端接地
Near-end of shield
line is grounded
Fig. 2-25 Connection diagram while using source of
external power (control board)
NOTE: Remove the short jumper JP1 connecting internal PLC
4) Use connection mode of drain electrode of an external power as shown in Fig. 2-27 (control board) and Fig. 2-28
(extension board).
22
24V
+
24V DC
COM
-
PLC
+
X1
-
+
X6
-
PE
board)
24V
+
24V DC
COM
-
PLC
+
X1
-
+
X6
-
PE
and 24V
External controller
外部控制器
5V
7
5V
10
Near-end of shield
屏蔽线近端接地
line is grounded
Fig. 2-24 Connection diagram while using drain
electrode of internal + 24V power supply (extension
NOTE: Remove the short jumper JP1 connecting PLC1 and
24V1, and connect PLC1 to COM1
External controller
外部控制器
9 ~ 30V
5V
+
-
7
5V
10
COM
屏蔽线近端接地
Near-end of shield
line is grounded
Fig. 2- 26 Connection diagram while using source of
external power (extension board)
NOTE: Remove the short jumper JP1 connecting internal PLC1
24V1
+
24V DC
COM1
-
PLC1
5V
+
X7
-
5V
+
X10
-
PE
board)
24V1
+
24V DC
COM1
-
PLC1
+
X7
-
+
X10
-
PE
and 24V1
5V
5V