Set fundamental frequency P0.09, maximum output voltage
按照电机铭牌设定基本频率P0.09、最大输出电压P0.1
P0.16, motor parameters P0.14, PA.01-PA.04 (PA.15-PA.18) in
6、电机参数P0.14、PA.01-PA.04(PA.15-PA.18)
P0.01 = 0 or 3, V/F control,
P0.01=0或3,V/F控制,
set V/F control parameters of
设定P9组V/F控制参数
Group P9
No
If the motor rotates in
若电机旋转方向错
wrong direction,
误,更改P2.37
change P2.37
Set extension parameters of PG, P2.42, P2.46, P2.49,
设置扩展PG参数P2.42、P2.46、P2.49、P2.50
Monitor running current and frequency, if an abnormality
监控运行电流和频率,如果出现异常则检查编
occurs, check pulses per revolution P2.42 of the encoder,
码器每转脉冲数P2.42、更改编码器方向P2.43或
change encoder direction P2.43 or power off and modify
If the motor rotates in the wrong direction, modify P2.37,
若电机旋转方向错误,修改P2.37、P2.43或断电并
P2.43 or power off and exchange any two-phase motor cable
交换任意两相电机线、编码器AB线后再上电
45
Start
开始
确认接线正确后上电
Power on after correct wiring
Recovery factory parameters
恢复出厂参数(设置PF.02=3)
(set PF.02 = 3)
accordance with the motor nameplate.
Control manner select
选择控制方式
Tuning of motor parameters: perform static parameter tuning PA.29 =
电机参数整定:带负载时实施静止参数整定PA.29=1;
1 when there is load; perform rotation parameter tuning PA.29 = 2
Auto-tuning start after pressing Run key, and it will
按下RUN键后开始自整定,整定完毕后自动停机
Press the JOG key for inching
按下JOG键点动运行
running
P0.01 closed loop vector
P0.01=1闭环矢量
(reserve for models below
(3004GB以下保留);
3004GB);
No
P2.50
断电修改编码器的接线
the wiring of the encoder
with encoder AB line, and then power on
Set the set frequency P0.02 ready to run
设置预备运行的设定频率P0.02
Press RUN key to
按RUN键运行
run the inverter
Press the STOP/RESET key
按STOP/RESET键停机
to stop the inverter
结束
End
Fig. 3-12 Operation process of inverter first test run operation
P0.01=1或2,矢量控制
P0.01 = 1 or 2, vector control
无负载时实施旋转整定PA.29=2
when there is no load
automatically shut down after tuning
Yes
Using built-in PG
使用内置PG
Setting built-in PG parameters P2.44, P2.46, P3.05,
设置内置PG参数P2.44、P2.46、P3.05、P3.06
P3.06 (models below 3004GB: P3.04, P3.05), P2.49,
(3004GB以下:P3.04、P3.05)、P2.49、P2.50;
Monitor running current and frequency, if an abnormality
监控运行电流和频率,如果出现异常则检查编
occurs, check pulses per revolution P2.44 of the encoder,
码器每转脉冲数P2.44、更改编码器方向P2.45或
change encoder direction P2.45 or power off and modify
the wiring of the encoder
If the motor rotates in the wrong direction, modify P2.37,
若电机旋转方向错误,修改P2.37、P2.45或断电并
P2.45 or power off and exchange any two-phase motor cable
交换任意两相电机线、编码器AB线后再上电
with encoder AB line, and then power on
Chapter 3 Operation
Yes
P2.50;
断电修改编码器的接线